BREAKING LOAD AND MASS FOR 8x19 Construction (9/9/1)
|
Nominal Diameter |
Approximate Mass
Weight |
Minimum Breaking Force Corresponding to Tensile Designation of Wires of |
1230 N/mm2 |
1420 N/mm2 |
1570 N/mm2 |
(1) |
(2) |
(3) |
(4) |
(5) |
mm |
kg/100 m |
kN |
kN |
kN |
8 |
22.3 |
23 |
26 |
29 |
9 |
28.2 |
29 |
33 |
37 |
10 |
34.8 |
35 |
41 |
45 |
11 |
42.2 |
43 |
49 |
55 |
12 |
50.2 |
51 |
59 |
65 |
13 |
58.9 |
60 |
69 |
76 |
14 |
68.3 |
69 |
80 |
88 |
16 |
89.2 |
90 |
104 |
115 |
18 |
113 |
114 |
132 |
146 |
19 |
126 |
127 |
147 |
163 |
20 |
139 |
141 |
163 |
180 |
Note: The nominal diameter 19mm is non-preferred.
|
|
|
BREAKING LOAD AND MASS FOR 6 x 19 Construction (12/6+6F/1)
|
Nominal Diameter |
Approximate Mass
Weight |
Minimum Breaking Force Corresponding to Tensile Designation of Wires of |
1230 N/mm2 |
1420 N/mm2 |
1570 N/mm2 |
(1) |
(2) |
(3) |
(4) |
(5) |
mm |
kg/100 m |
kN |
kN |
kN |
6 |
13.7 |
15.0 |
17.3 |
19.1 |
7 |
18.6 |
20.4 |
23 |
26 |
8 |
24.3 |
27 |
31 |
34 |
9 |
30.8 |
34 |
39 |
43 |
10 |
38.0 |
42 |
48 |
53 |
11 |
46.0 |
50 |
58 |
64 |
12 |
54.7 |
60 |
69 |
76 |
13 |
64.3 |
70 |
81 |
90 |
14 |
74.5 |
81 |
94 |
104 |
16 |
97.3 |
106 |
123 |
136 |
18 |
123 |
135 |
155 |
172 |
19 |
137 |
150 |
173 |
191 |
20 |
152 |
166 |
192 |
212 |
Note: The nominal diameter 19mm is non-preferred.
|
|