Measured Capacity -1500 Tons from sizes 44 mm to 80 mm



Actual picture of 65 mm Dia Steel Wire Rope Sling Spliced using the above Single Bite System
Alluminium Alloy Ferrules Slings Mechanically Spliced
Splices on Single Bite continuous radial pressure, forming one strong homogenous mass, simple procedure & stronger as Breaking Strength of the rope.
SPLICING SYSTEM
  Wire Rope Min-Max Diameter (mm) Pressing Limit  
Ferrule Code No. UM Fill factor
(f=0,4-0,5)
Fiber Core
Fill factor
(f=0,5-0,6)
Steel Core
Dia. after Pressing Required pressure Approx.
UM Min   Max Min    Max (mm) / Tol. (kN)
44 43,7  45,7 39,9  41,7 84 +1,3 9 700
50 48,1  50,6 43,9  46,2 92 12 500
58 55,1  59,4 50,3  54,2 108 0 16 800
62 59,5  63,8 54,3  58,2 116 +1,7 19 200
66 63,9  67,6 58,3  61,7 124 +1,8 22 000
70 67,7  71,9 61,8  65,6 132 0 24 500
74 72,0  76,3 65,7  69,7 140 +2,0 27 000
78 76,4  80,7 69,8  73,6 148 0 30 000
82 80,8  85,0 73,7  77,6 156 34 000
f= Fill factor, is the ratio between the sum of the nominal metallic cross-sectional areas of all the wires in the rope and the circumscribed areas of the rope based on its nominal diameter.
C= Nominal Metallic cross-sectional area factor of the rope.
C=
UM-ferrule have been validated according to EN 13411-3 regarding Ferrule Secured Eye terminations and Ferrule Secured endless slings. The table applies to bright or galvanized single layer steel wire ropes with round strands. Maximum rope grade is 1960. For Fiber core wire ropes larger than 60 mm the maximum rope grade is 1770. Wire ropes shall conform to IS:2266-89. The types of rope shall be Ordinary or Lang lay. For higher tensile grade and higher Fill factor, please contact us.
Stages Explaining method of Splicing
Stages Explaining method of Splicing