Measured Capacity -1500 Tons from sizes 44 mm to 80 mm
Actual picture of 65 mm Dia Steel Wire Rope Sling Spliced using the above Single Bite System
|
Alluminium Alloy Ferrules Slings Mechanically Spliced
Splices on Single Bite continuous radial pressure, forming one strong homogenous mass, simple procedure & stronger as Breaking Strength of the rope.
SPLICING SYSTEM
|
Wire Rope Min-Max Diameter (mm) | Pressing Limit |
|
Ferrule Code No. UM |
Fill factor
(f=0,4-0,5)
Fiber Core |
Fill factor
(f=0,5-0,6)
Steel Core |
Dia. after Pressing |
Required pressure Approx. |
UM |
Min Max |
Min Max |
(mm) / Tol. |
(kN) |
44 |
43,7 45,7 |
39,9 41,7 |
84 |
+1,3 |
9 700 |
50 |
48,1 50,6 |
43,9 46,2 |
92 |
|
12 500 |
58 |
55,1 59,4 |
50,3 54,2 |
108 |
0 |
16 800 |
62 |
59,5 63,8 |
54,3 58,2 |
116 |
+1,7 |
19 200 |
66 |
63,9 67,6 |
58,3 61,7 |
124 |
+1,8 |
22 000 |
70 |
67,7 71,9 |
61,8 65,6 |
132 |
0 |
24 500 |
74 |
72,0 76,3 |
65,7 69,7 |
140 |
+2,0 |
27 000 |
78 |
76,4 80,7 |
69,8 73,6 |
148 |
0 |
30 000 |
82 |
80,8 85,0 |
73,7 77,6 |
156 |
|
34 000 |
f= Fill factor, is the ratio between the sum of the nominal metallic cross-sectional areas of all the wires in the rope and the circumscribed areas of the rope based on its nominal diameter.
C= Nominal Metallic cross-sectional area factor of the rope.
C=
|